• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • AASHTO - American Association of State Highway and Transportation Officials
  • View Item
  •   YSE
  • Industrial Standards
  • AASHTO - American Association of State Highway and Transportation Officials
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

AASHTO R 59

Standard Practice for Recovery of Asphalt Binder from Solution by Abson Method

Organization:
AASHTO - American Association of State Highway and Transportation Officials
Year: 2015

Abstract: This practice covers the recovery, by the Abson Method, of asphalt binder from a previously conducted extraction with reagent-grade trichloroethylene or reagent-grade methylene chloride (Note 1). The asphalt binder is recovered with properties substantially the same as those it possessed in the asphalt mixture and in quantity sufficient for further testing.
Note 1—Trichloroethylene conforming to ASTM D4080 or technical-grade methylene chloride may be used, but it is recommended that for each new supply of the solvent a "blank" recovery as described below be performed on an asphalt binder of known properties. Certain epoxy resins in some non-reagent-grade solvents may affect the properties of the recovered binder. In case of dispute, reagent grade should be used. 1.2.
Blank Determinations—Introduce about 75 to 100 g of asphalt binder into a 2000-mL (68-oz) flask; add about 800 mL (27 oz) of solvent to dissolve the asphalt. Allow the solution to stand for about 4 h; concentrate the solution by distillation to about 200 mL (6.8 oz), and then recover the asphalt binder. The total elapsed time, from when the solvent is added to the time the recovery test is completed, is about 7 h.
The values stated in SI units are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
URI: https://yse.yabesh.ir/std/handle/yse/49441
Collections :
  • AASHTO - American Association of State Highway and Transportation Officials
  • Download PDF : (953.0Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    AASHTO R 59

Show full item record

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2017-09-04T15:46:43Z
date available2017-09-04T15:46:43Z
date copyright2011.01.01 (R 2015)
date issued2015
identifier otherPWCXKFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/49441
description abstractThis practice covers the recovery, by the Abson Method, of asphalt binder from a previously conducted extraction with reagent-grade trichloroethylene or reagent-grade methylene chloride (Note 1). The asphalt binder is recovered with properties substantially the same as those it possessed in the asphalt mixture and in quantity sufficient for further testing.
Note 1—Trichloroethylene conforming to ASTM D4080 or technical-grade methylene chloride may be used, but it is recommended that for each new supply of the solvent a "blank" recovery as described below be performed on an asphalt binder of known properties. Certain epoxy resins in some non-reagent-grade solvents may affect the properties of the recovered binder. In case of dispute, reagent grade should be used. 1.2.
Blank Determinations—Introduce about 75 to 100 g of asphalt binder into a 2000-mL (68-oz) flask; add about 800 mL (27 oz) of solvent to dissolve the asphalt. Allow the solution to stand for about 4 h; concentrate the solution by distillation to about 200 mL (6.8 oz), and then recover the asphalt binder. The total elapsed time, from when the solvent is added to the time the recovery test is completed, is about 7 h.
The values stated in SI units are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
languageEnglish
titleAASHTO R 59num
titleStandard Practice for Recovery of Asphalt Binder from Solution by Abson Methoden
typestandard
page10
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2015
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian