MIL-D-22612C

DETECTOR, CONTAMINATED FUEL

Organization:
NAVY - AS - Naval Air Systems Command
Year: 1980

Abstract: This specification establishes the requirements for three types of contaminated fuel detectors.
The contaminated fuel detectors covered by this specification shall be classified as follows:
          Type I   - Hand operated pump           Type II  - Motorized pump           Type III - Motorized pump with free water detection capability


Intended Use: The detectors covered by this specification are intended for use at Naval shore activities and aboard ships where fuel is dispensed to aircraft. The basic contaminated fuel detector is a portable instrument which is utilized to quickly determine the quantity of solid contamination present in aircraft fuels. The detector processes a sample of an aircraft fuel on site in usually three to four minutes, and establishes the level of contamination in the fuel. The level of contamination is measured by using the principle of differences in light transmission through membrane filters. For greater accuracy and to eliminate any fuel color effect, the two membrane filters are used in series. The first filter traps the solid contaminant, plus any fuel color effect. The second filter is subjected to only fuel color effects. The light transmission through the two filters is measured by a light sensitive cell system. Determining the difference between the amount of light transmitted through the contaminated and clean filters establishes the level of solid contamination in the fuel. The established level is evaluated with the calibration curve supplied with each detector to ascertain if the fuel is contaminated beyond required limits. All components necessary for filtration and measuring of transmitted light are incorporated into this one serviceable instrument.
URI: https://yse.yabesh.ir/std/handle/yse/80278
Collections :
  • NAVY - AS - Naval Air Systems Command
  • Download PDF : (771.0Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-D-22612C

Show full item record

contributor authorNAVY - AS - Naval Air Systems Command
date accessioned2017-09-04T16:16:58Z
date available2017-09-04T16:16:58Z
date copyright07/30/1980
date issued1980
identifier otherTBHLDAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/80278
description abstractThis specification establishes the requirements for three types of contaminated fuel detectors.
The contaminated fuel detectors covered by this specification shall be classified as follows:
          Type I   - Hand operated pump           Type II  - Motorized pump           Type III - Motorized pump with free water detection capability


Intended Use: The detectors covered by this specification are intended for use at Naval shore activities and aboard ships where fuel is dispensed to aircraft. The basic contaminated fuel detector is a portable instrument which is utilized to quickly determine the quantity of solid contamination present in aircraft fuels. The detector processes a sample of an aircraft fuel on site in usually three to four minutes, and establishes the level of contamination in the fuel. The level of contamination is measured by using the principle of differences in light transmission through membrane filters. For greater accuracy and to eliminate any fuel color effect, the two membrane filters are used in series. The first filter traps the solid contaminant, plus any fuel color effect. The second filter is subjected to only fuel color effects. The light transmission through the two filters is measured by a light sensitive cell system. Determining the difference between the amount of light transmitted through the contaminated and clean filters establishes the level of solid contamination in the fuel. The established level is evaluated with the calibration curve supplied with each detector to ascertain if the fuel is contaminated beyond required limits. All components necessary for filtration and measuring of transmitted light are incorporated into this one serviceable instrument.
languageEnglish
titleMIL-D-22612Cnum
titleDETECTOR, CONTAMINATED FUELen
typestandard
page13
statusActive
treeNAVY - AS - Naval Air Systems Command:;1980
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian