Now showing items 21-40 of 71

    • MIL-PRF-5350G 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2009
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This general specification covers aircraft synchro transmitters (see 6.3.2).Intended Use: The synchro transmitters are intended to sense variable data and transmit signals dependent on their magnitudes to ...
      Subject(s) : 26Vac ,
    • MS29571 REV E 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2013
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
    • MIL-STD-188-110C CHANGE 1 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2012
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This document establishes mandatory technical standards and design objectives (DO) that are necessary to ensure interoperability and to promote performance among data modulatorsdemodulators (modems) used in the voice ...
      Subject(s) : 16-tone DPSK mode , 39-tone parallel mode , Asynchronous , DPSK , Error-correcting code , Fallback Operation , Fixed-frequency , Frequency hopping , FSK , Full-duplex , Half-duplex , HF data modems , In-band signaling , Interleaving , Modified gray decoder , Modulator/demodulator , PSK , QAM , Quasi-analog signals , Randomizing generator , Scrambler , Serial (single tone) , Synchronous ,
    • MIL-PRF-25439C 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2013
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers one type of in-flight refueling rate of flow and fuel transmitter, designated Type MB-3.Intended Use: The MB-3 transmitter is intended for use I a fuel flowmeter system used for ...
    • MIL-T-7305C 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;1987
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers one type of remote indicating torque pressure transmitter, designated D-5. Intended Use: The type D-5 transmitter is intended for use as a transmitter component of a torque pressure ...
      Subject(s) : Military specification , Transmitter , Pressure , Torque , Type D-5 ,
    • MIL-DTL-5882E 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2013
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers one type of remote indicating, 320 degrees movement synchro style, general purpose pressure gage transmitter.Intended Use: The multipurpose pressure transmitter covered by this ...
    • MIL-PRF-83860D 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2013
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers disposable hydraulic line filter elements that retain all particles larger than 5 microns. For use, the element is inserted in a canister prior to use in a Hydraulic system, and is intended for ...
    • DI-MISC-81454B 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2009
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: Use/relationship: The ACPIN Data and control record provides for the assignment of a CPIN for embedded computer system software. The CPIN is used by the government for configuration management of software ...
    • MIL-PRF-83178C 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2009
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers the general requirements for a panel mounted automatic-pressure-breathing, diluter-demand, oxygen regulator, designated CRU-73A.Intended Use: The regulator covered by this specification ...
      Subject(s) : Elastomers , Flow indicator , Gage , Leakage , Lever , Outlet leakage , Panel lighting ,
    • MIL-DTL-7891G VALID NOTICE 1 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2013
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
    • MIL-PRF-38230D (1) 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2011
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers oil pressure transmitters.Intended Use: The transmitters covered by this specification are intended for use with variable-reluctance-type indicators conforming to MIL-I-25437, ...
      Subject(s) : 0-100 PSI , TRU-66/A , Variable reluctance ,
    • MIL-PRF-25478D 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2013
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This is general specification for aircraft engine lubricating oil coolers that provide oil temperature regulation for aircraft gas turbine engines using high temperature synthetic base lubricating oil, and aircraft piston ...
    • MIL-PRF-7908E 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2009
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers aircraft low pressure oxygen check valves.Intended Use: The check valves are intended for use in low pressure, 450 psig or less, aircraft oxygen systems.
      Subject(s) : 450 psig ,
    • MIL-PRF-25962E 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2008
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers one type of valve for draining 70 and 300 pounds per square inch gage (psig) liquid oxygen converters. Intended Use: The valve covered by this specification is intended to be used ...
    • QPL-38121-12 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;1992
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This list has been prepared for use by or for the Government in the acquisition of products covered by the subject specification and such listing of a product is not intended to and does not connote indorsement of the ...
    • MIL-PRF-38214D VALID NOTICE 1 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2013
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
    • QPL-25597-21 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;1996
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This list has been prepared for use by or for the Government in the acquisition of products covered by the subject specification and such listing of a product is not intended to and does not connote endorsement of the ...
    • MIL-PRF-26392E VALID NOTICE 1 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2013
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
    • MIL-PRF-6164G (1) 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;2013
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers several types of high-pressure pneumatic valves for aircraft use.Intended Use: The high pressure air valves covered by this specification are intended for use in gas-charged units ...
    • MIL-T-5420B 

      Type: standard
      Source: AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins:;1970
      Organization : AIR FORCE - 84 - Air Force Sustainment Center - Warner Robins
      Abstract: This specification covers two types of two-wire electrically heated pitot static tubes identified as follows:
              Type I  Rated Voltage - 24 volt, direct current (DC)                 AN5814-2        "L" ...