• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

IEEE N323B

Radiation Protection Instrumentation Test and Calibration, Portable Survey Instrumentation for Near Background Operation

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2003

Abstract: This standard establishes minimum acceptance performance requirements for portable radiation protection instruments used for detection and measurement of ionizing radiation fields or levels of radioactive surface contamination that are near background.
For purposes of this standard, portable radiation protection instruments are those battery-powered instruments that are carried to a specific facility or location for use.
Specifically, this standard is intended to apply to those instruments utilized to make in-situ measurements for confirmation of residual radioactivity levels that are below criteria established to permit the unrestricted release of a surface area or component from further regulatory controls.
This standard is intended to define performance requirements and acceptance testing that supplements those established in ANSI N42.17A-1989 [B7] and ANSI N42.17C-1989 [B8], and to define calibration requirements that supplement those established in ANSI N323A-1998 [B6].1 This standard is applicable to the measurement of gamma, beta, and alpha radiation emissions only. This standard addresses the instrument response requirements for the same range of surface activity covered by the above ANSI standards, but extends the applicable range of dose-rate response below those standards. This is illustrated in Table 1.
Throughout this standard, three verbs have been used to indicate the degree of rigor intended for each specific test or performance criterion. The word “shall” is used to denote a requirement; the word “should” to denote a recommendation; and the word “may” to denote a permissible practice.
URI: http://yse.yabesh.ir/std/handle/yse/109969
Subject: instrumentation
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (407.6Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE N323B

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T16:46:41Z
date available2017-09-04T16:46:41Z
date copyright09/30/2003
date issued2003
identifier otherWDAPEBAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/109969
description abstractThis standard establishes minimum acceptance performance requirements for portable radiation protection instruments used for detection and measurement of ionizing radiation fields or levels of radioactive surface contamination that are near background.
For purposes of this standard, portable radiation protection instruments are those battery-powered instruments that are carried to a specific facility or location for use.
Specifically, this standard is intended to apply to those instruments utilized to make in-situ measurements for confirmation of residual radioactivity levels that are below criteria established to permit the unrestricted release of a surface area or component from further regulatory controls.
This standard is intended to define performance requirements and acceptance testing that supplements those established in ANSI N42.17A-1989 [B7] and ANSI N42.17C-1989 [B8], and to define calibration requirements that supplement those established in ANSI N323A-1998 [B6].1 This standard is applicable to the measurement of gamma, beta, and alpha radiation emissions only. This standard addresses the instrument response requirements for the same range of surface activity covered by the above ANSI standards, but extends the applicable range of dose-rate response below those standards. This is illustrated in Table 1.
Throughout this standard, three verbs have been used to indicate the degree of rigor intended for each specific test or performance criterion. The word “shall” is used to denote a requirement; the word “should” to denote a recommendation; and the word “may” to denote a permissible practice.
languageEnglish
titleIEEE N323Bnum
titleRadiation Protection Instrumentation Test and Calibration, Portable Survey Instrumentation for Near Background Operationen
typestandard
page38
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2003
contenttypefulltext
subject keywordsinstrumentation
subject keywordsnear background
subject keywordsportable survey
subject keywordsradiation
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian