NFPA - (NFPA) - National Fluid Power Association: Recent submissions
Now showing items 981-1000 of 1485
-
NFPA 1150
Abstract: This standard specifies requirements for foam and the chemicals used to produce foam that is used to control, suppress, or prevent fires in Class A fuels.
Purpose.
The purpose of this standard is ... -
NFPA 16
Abstract: This standard contains minimum requirements for the design, installation, and maintenance of foam-water sprinkler and spray systems. These systems shall be designed with the required density for either foam or water ... -
NFPA 407
Abstract: This standard applies to the fuel servicing of all types of aircraft using liquid petroleum fuel. It does not apply to any of the following:
(1) In-flight fueling
(2) Fuel servicing of flying boats or amphibious ... -
NFPA 497M
Abstract: This manual provides information on specific flammable gases, flammable and combustible liquids, and combustible dusts whose relevant combustion properties have been identified sufficiently to allow their classification ... -
NFPA 99
Abstract: The scope of this code is to establish minimum criteria as follows in 1.1.2 through 1.1.13.
Fundamentals. Chapter 4 establishes criteria for levels of health care services or systems based on risk to ... -
NFPA 1670
Abstract: This standard shall identify and establish levels of functional capability for conducting operations at technical search and rescue incidents while minimizing threats to rescuers.
The requirements of this standard shall ... -
NFPA 220
Abstract: This standard defines types of building construction based on the combustibility and the fire resistance rating of a building's structural elements. Fire walls, nonbearing exterior walls, nonbearing interior partitions, ... -
NFPA 1720
Abstract: This standard contains minimum requirements relating to the organization and deployment of fire suppression operations, emergency medical operations, and special operations to the public by volunteer and combination fire ... -
NFPA 69
Abstract: This standard applies to the design, installation, operation, maintenance, and testing of systems for the prevention of explosions by means of the following methods:
(1) Control of oxidant concentration
(2) Control ... -
NFPA 260
Abstract: The tests described in this document apply to upholstered furniture components that are tested in a standard, defined composite.
These tests shall apply to cover fabrics, interior fabrics, welt cords, decking materials, ... -
NFPA 86
Abstract: This standard shall apply to Class A, Class B, Class C, and Class D ovens, dryers, and furnaces; thermal oxidizers; and any other heated enclosure used for processing of materials and related equipment.
The terms ovens, ... -
NFPA 302
Abstract: This standard shall establish minimum requirements for the prevention of fire and explosion, and for life safety in case of fire, on boats specified in Section 1.3.
This standard shall establish minimum requirements for ... -
NFPA 2113
Abstract: This standard shall specify the minimum selection, care, use, and maintenance requirements for flame-resistant garments for use by industrial personnel in areas at risk from short-duration thermal exposures from industrial ... -
NFPA 59A
Abstract: This standard shall apply to the following:
(1) Facilities that liquefy natural gas
(2) Facilities that store, vaporize, transfer, and handle liquefied natural gas (LNG)
(3) The training of all personnel involved ...

درباره ما