MIL-V-24761
VENTILATING SETS, PORTABLE DAMAGE CONTROL
Organization:
NAVY - SH - Naval Sea Systems Command (Ship Systems)
Year: 1991
Abstract: This specification covers Navy standard portable damage control ventilating sets. Navy standard portable damage control ventilating sets are either electric-motor driven vaneaxial fans or air-turbine driven centrifugal fans. Intended Use: The portable damage control ventilating sets specified herein are intended to be used for damage control purposes only aboard Navy ships. Class 0-½A and 0-½D fans, available in a single size, are rated at 500 ft3/min at 2.5 inches water gauge static pressure. They are used with ventilation hose and fittings, which may be attached to the fan inlet or outlet. Exterior surfaces of fans and fittings are of aluminum to avoid sparking when bumped against steel bulkheads. They are vaneaxial fans driven with electrical motors that have explosionproof enclosures. Class 0-¾T fans, available in a single size, are rated at 750 ft3/min and 3.0 inches water gauge static pressure. They are used with ventilation hose and fittings, which may be attached to the fan inlet or outlet. Exterior surfaces of fans and fittings are of aluminum to avoid sparking when bumped against steel bulkheads. They are air-turbine driven centrifugal fans.
Subject: Air-turbine driven
Collections
:
Show full item record
contributor author | NAVY - SH - Naval Sea Systems Command (Ship Systems) | |
date accessioned | 2017-09-04T17:55:31Z | |
date available | 2017-09-04T17:55:31Z | |
date copyright | 06/17/1991 | |
date issued | 1991 | |
identifier other | FKDWDAAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std/handle/yse/178687 | |
description abstract | This specification covers Navy standard portable damage control ventilating sets. Navy standard portable damage control ventilating sets are either electric-motor driven vaneaxial fans or air-turbine driven centrifugal fans. Intended Use: The portable damage control ventilating sets specified herein are intended to be used for damage control purposes only aboard Navy ships. Class 0-½A and 0-½D fans, available in a single size, are rated at 500 ft3/min at 2.5 inches water gauge static pressure. They are used with ventilation hose and fittings, which may be attached to the fan inlet or outlet. Exterior surfaces of fans and fittings are of aluminum to avoid sparking when bumped against steel bulkheads. They are vaneaxial fans driven with electrical motors that have explosionproof enclosures. Class 0-¾T fans, available in a single size, are rated at 750 ft3/min and 3.0 inches water gauge static pressure. They are used with ventilation hose and fittings, which may be attached to the fan inlet or outlet. Exterior surfaces of fans and fittings are of aluminum to avoid sparking when bumped against steel bulkheads. They are air-turbine driven centrifugal fans. | |
language | English | |
title | MIL-V-24761 | num |
title | VENTILATING SETS, PORTABLE DAMAGE CONTROL | en |
type | standard | |
page | 41 | |
status | Active | |
tree | NAVY - SH - Naval Sea Systems Command (Ship Systems):;1991 | |
contenttype | fulltext | |
subject keywords | Air-turbine driven | |
subject keywords | Alternating current motors | |
subject keywords | Direct current motors | |
subject keywords | Electric-motor driven | |
subject keywords | Fan sets | |
subject keywords | Fan units | |
subject keywords | Portable fans |