Now showing items 121-140 of 258

    • ISA TR18.2.5 

      Type: standard
      Source: ISA - International Society of Automation:;2012
      Organization : ISA - International Society of Automation
      Abstract: This technical report was written in support of the standard ANSI/ISA-18.2-2009, Management of Alarm Systems for the Process Industries (June 2009). This technical report is designed to provide guidance, rationale, and ...
    • ISA 95.00.04 

      Type: standard
      Source: ISA - International Society of Automation:;2012
      Organization : ISA - International Society of Automation
      Abstract: This ISA-95 Part 4 standard, in conjunction with ANSI/ISA-95.00.03-2005, Enterprise-Control System Integration–Part 3: Activity Models of Manufacturing Operations Management, specifies interface content between ...
    • ISA 5.3 

      Type: standard
      Source: ISA - International Society of Automation:;1983
      Organization : ISA - International Society of Automation
      Abstract: This standard satisfies the requirements for symbolically representing the functions of distributed ControVshared display instrumentation, logic, and computer systems. The instrumentation is generally composed of field ...
    • ISA 77.20.01 

      Type: standard
      Source: ISA - International Society of Automation:;2012
      Organization : ISA - International Society of Automation
      Abstract: The scope of this standard is to address the simulation of fossil fuel power plants typically consisting of:
      • Boiler, turbine, and balance of plant with steaming capacities of 200,000 lbs/hr (25 kg/s) or greater ...
    • ISA RP60.8 

      Type: standard
      Source: ISA - International Society of Automation:;1978
      Organization : ISA - International Society of Automation
      Abstract: This Section of ISA-RP60 is intended to assist the design engineer in establishing the electrical requirements of a control center; it is also intended to comply with the provisions of the National Electrical Code. What ...
    • ISA RP92.04.02 PART II 

      Type: standard
      Source: ISA - International Society of Automation:;2013
      Organization : ISA - International Society of Automation
      Abstract: ISA-RP92.04.02, Part II, applies to all oxygen detection instruments that satisfy the performance requirements in ANSI/ISA-S92.04.01, Part I, Performance Requirement for Instruments Used to Detect Oxygen-Deficient/Ox ...
    • ISA 67.06.01 

      Type: standard
      Source: ISA - International Society of Automation:;2002
      Organization : ISA - International Society of Automation
      Abstract: This standard provides the nuclear power industry methods for assuring that nuclear safety-related instrument channels satisfy acceptable calibration, response time, and other factors affecting the performance of the ...
    • ISA RP60.6 

      Type: standard
      Source: ISA - International Society of Automation:;1984
      Organization : ISA - International Society of Automation
      Abstract: This Recommended Practice is intended to summarize identification methods and to suggest the uses of nameplates, labels, and tags. Examples are included for guidance in preparing drawings and specifications. (See Appendix ...
    • ISA 67.04.01 

      Type: standard
      Source: ISA - International Society of Automation:;2011
      Organization : ISA - International Society of Automation
      Abstract: This standard defines the requirements for assessing, establishing, and maintaining nuclear safety-related and other important instrument setpoints associated with nuclear power plants or nuclear reactor facilities. The ...
    • ISA 77.82.01 

      Type: standard
      Source: ISA - International Society of Automation:;2011
      Organization : ISA - International Society of Automation
      Abstract: This standard will address the control functions associated with the selective catalytic reduction systems on fossil-fired steam boilers greater than 200,000 lbs/hr and combustion turbines greater than 25 megawatts. This ...
    • ISA RP12.13.02 

      Type: standard
      Source: ISA - International Society of Automation:;2003
      Organization : ISA - International Society of Automation
      Abstract: ANSI/ISA-RP12.13.02 (IEC 61779-6 Mod) gives guidance on the selection, installation, use, and maintenance of electrically operated group II apparatus for the detection and measurement of flammable gases complying ...
    • ISA 91.00.01 

      Type: standard
      Source: ISA - International Society of Automation:;2001
      Organization : ISA - International Society of Automation
      Abstract: This standard addresses the instruments that are classified as emergency shutdown systems and safety critical controls and establishes requirements for testing and documenting the test results of these systems.
      This ...
    • ISA TR12.13.01 

      Type: standard
      Source: ISA - International Society of Automation:;2010
      Organization : ISA - International Society of Automation
      Abstract: Introduction
      Prevention of unwanted fires and gas explosion disasters requires a knowledge of flammability characteristics (limits of flammability, ignition requirements, and burning rates) of pertinent ...
      Subject(s) : Combustible , Explosion , Fire , Flammability limits , Flammable , Gas , LEL , UEL , LFL , UFL , Methane ,
    • ISA TR84.00.02 

      Type: standard
      Source: ISA - International Society of Automation:;2015
      Organization : ISA - International Society of Automation
      Abstract: ISA-TR84.00.02-2015 is informative and does not contain any mandatory clauses. ISA-TR84.00.02 is intended for use by those with a thorough understanding of ISA-84.00.01-2004 Part 1. This document assumes that a SIS is ...
    • ISA 12.01.01 

      Type: standard
      Source: ISA - International Society of Automation:;2013
      Organization : ISA - International Society of Automation
      Abstract: This document provides general guidance for safe design, installation, and maintenance of electrical equipment in hazardous (classified) locations using appropriate means to prevent ignition of flammable gases and vapors, ...
    • ISA TR84.00.05 

      Type: standard
      Source: ISA - International Society of Automation:;2009
      Organization : ISA - International Society of Automation
      Abstract: ISA-TR84.00.05 is strictly informative and does not contain any mandatory requirements.
      ISA-TR84.00.05 is intended to be used by those with an understanding of the basic requirements of ANSI/ISA-84.00.01-2004 and other ...
    • ISA 107.1 

      Type: standard
      Source: ISA - International Society of Automation:;2013
      Organization : ISA - International Society of Automation
      Abstract: This standard presents the file format to be utilized for data acquired by a revolution-based tip timing data system. It provides the following:
      • All header information needed to describe the contents of the ...
    • ISA TR61804-4 

      Type: standard
      Source: ISA - International Society of Automation:;2007
      Organization : ISA - International Society of Automation
      Abstract: This part of IEC 61804 is a guideline to support EDD interoperability.This Technical Report is intended to ensure that field device developers use the EDDL constructs consistently and that the EDD applications have the ...
    • ISA 12.13.04 

      Type: standard
      Source: ISA - International Society of Automation:;2007
      Organization : ISA - International Society of Automation
      Abstract: This standard provides minimum requirements for fixed and transportable open path gas detection apparatus.
      This standard specifies the construction, performance and testing of open path (line-of-sight) gas monitors ...
    • ISA 12.00.02 

      Type: standard
      Source: ISA - International Society of Automation:;2009
      Organization : ISA - International Society of Automation
      Abstract: This standard defines minimum elements and format for certificates for AEx equipment to align with those for the IECEx Certificate of Conformity.
      NOTE 1 — This standard may be used for other than AEx equipment ...